Tu carrito

microscopio trinocular invertido digital de larga distancia de trabajo amscope in300tc-10m, oculares 40x-1000x, wh10x y wh25x, objetivos de contraste de fase, iluminación halógena de 30 w, condensador abbe de 0,3 na, platina mecánica, 110 v, incluye cámar

  • Marca:

    amscope

  • Código producto: B006L0RHOA
  • Disponibilidad: Traemos a pedido, tiempo de 15 a 25 dias.
  • $CLP 6.358.506

TÉRMINOS Y CONDICIONES

------------------------------------------

- El producto se trae a pedido, en un transcurso de 15 a 25 dias, si alguna restriccion de un ente gubernamental o de salud publica cambia o restringe vuelos, los pedidos pueden demorar mas tiempo.
- Precios pueden cambiar previo aviso. Depende de precio con proveedores o existencia.
- Fotos referenciales del producto, consulte no mas
- Despachamos a todo Chile con Starken.
- Productos importados de Estados Unidos, es probable que los productos electronicos trabajen en 110V y NO en 220V, podria usar un transformador, para mas informacion primero nos puedes preguntar todas las inquietudes que tengas.
-Digital inverted compound microscope for observation of biological cultures or specimens within well plates, petri dishes, or vials that require a longer working distance, and a 10MP camera with reduction lens and USB 2.0 output for capturing or displaying images on a computer or projector
-Trinocular head with Siedentopf binocular mount, interchangeable pairs of 10x and 25x high-eyepoint super-widefield eyepieces, 50 to 75mm interpupillary adjustment, and fixed 45-degree vertical inclination; vertical port accepts C-Mount or 23mm camera
-Under-mounted quadruple nosepiece with 4x, 10x (phase-contrast), 20x (phase-contrast), and 40x DIN long working-distance plan objectives that provide a longer working distance and improved focus over the entire viewing field
-Upper-mounted rheostat-controlled 30W halogen illumination and movable 0.3 NA Abbe condenser for clear examination and light control
-Oversize double-layer mechanical stage with 1.0mm stage divisions and 0.1mm vernier resolution locks slide into place and provides precise slide manipulation along the X- and Y-axis; with coaxial coarse and fine focus

The AmScope IN300TC-10M digital inverted trinocular compound microscope has interchangeable pairs of 10x22mm and 25x10mm high-eyepoint super-widefield eyepieces, an under-mounted quadruple nosepiece with four DIN long working-distance plan objectives, top-mounted Brightfield 30W halogen illumination, a 0.3 NA Abbe condenser with iris diaphragm, and a double-layer mechanical stage with a stage stop to protect slides and objectives from damage. The 10MP camera has a CMOS color sensor, a reduction lens, image capture and editing software, and USB 2.0 output to capture or display still or video images on a computer or projector. The anti-mold trinocular head has a Siedentopf binocular mount with 50 to 75mm interpupillary adjustment and a fixed 45-degree vertical inclination to reduce eye and neck strain. A Siedentopf binocular head enables the viewer to change the interpupillary distance without changing the tube length, eliminating the need to refocus the image. Anti-mold coatings protect the microscope in high-humidity environments. Interchangeable pairs of WH10x22mm and WH25x10mm high-eyepoint super-widefield eyepieces provide improved focus over the entire field of view (FOV). High-eyepoint objectives ease viewing for viewers who wear glasses. Dioptric adjustment on both eyepieces accommodates individual eye-strength differences. The vertical trinocular port accepts a 23mm or C-Mount camera. The under-mounted nosepiece has 4x, 10xPH (phase-contrast), 20xPH (phase-contrast), and 40x (spring) DIN long working-distance plan objectives that combine with the eyepieces to provide color correction of magnified images. Long working-distance plan objectives provide improved focus over the entire range of the viewing field and a longer working distance that is required when viewing specimens in dishes and large containers. Phase-contrast provides high contrast and visibility without the use of stains, allowing specimens to be observed in their natural state without being killed or fixed. An inverted microscope has its light source above the stage pointing downward and the objectives and turret below the stage pointing upward. It is most often used for observing organisms in a large container, such as a well plate or petri dish. It can also be used when specimens require manipulation, or in metallurgical applications. The 10MP digital camera has a CMOS color sensor for displaying still microscopy images and streaming live videos to a computer or projector. The camera has 40x magnification and a 0.5x reduction lens that ensures that the display has a similar field of view as the microscope eyepiece. The camera can be mounted in a C-Mount or any 23mm eye tube. The camera includes image capture and editing software that provides still image and live video capture and editing capability, including measurement functions. The software supports JPG, TIF, GIF, PSD, WMF, and BMP file formats and is compatible with Windows XP, Vista, 7, and 8; Mac OS X; and Linux. Camera drivers are compatible with Windows XP, Vista, 7, and 8; Mac OS X; and Linux. The software includes Windows APIs for native C/C++, C#, DirectShow, Twain, and LabVIEW that enable custom application development. The camera has a USB 2.0 data port (cable included).Brightfield and phase-contrast illumination is mounted above the stage and has transmitted 30W halogen illumination. Brightfield (BF) illumination allows the specimen to absorb light, resulting in a dark image on a light background. The phase-contrast element aligns the light source with the phase-contrast objectives to optimize high contrast and visibility without the use of stains, allowing specimens to be observed in their natural state without being killed or fixed. Halogen illumination provides bright light in a concentrated path, and a rheostat controls the amount of light emanating from the lamp. The movable 0.3 NA Abbe condenser can be adjusted to control the distance of the light from the stage, and the iris diap